Sub-Zero is the epitome of style as well as performance refrigeration. It isn’t just a device, your Sub-Zero is an essential element of your perfect cooking area. It makes good sense that you wouldn’t want to trust your fridge to simply any type of appliance repair service firm. You desire a team of Sub-Zero refrigerator fixing specialists that can secure your investment while supplying the premium solution you should have.
It Is Fixed Appliance Repair work is the firm you must rely on with all of your Sub-Zero fixing demands. Our specialists specialize in Sub-Zero solution so you can trust that we have the abilities to do the job right.
HOW TO USE THE ERROR CODE TROUBLESHOOTING GUIDE
Error Codes show problems signed up by specific parts. If mistake codes are signed up, they will show up before temperature analyses while in Diagnostic Setting.
KEEP IN MIND: If Error Codes appear with a blinking “SERVICE” annunciator before initiating Diagnostic Mode, the device experienced excessive compressor run condition that may or might not be related to the Error Codes presented
To initiate Diagnostic Setting, press and hold either COLDER key, then press the POWER key, after that launch both keys. Now, examine to see if Mistake Codes exist, being sure to toggle with all error as well as temperature readings by pressing either COLDER essential or either WARMER secret. (See Mistake Code Table Below).
If Mistake Codes show up during Diagnostic Mode, comply with the Mistake Code Troubleshooting Guide on the adhering to page. The left column of the troubleshooting guide lists the error codes. The information in the best column explains what tests to do and/or what action to require to correct the mistake.
NOTE: If mistake codes are observed in diagnostic mode, a non-flashing SOLUTION annunciator will show up on the LCD when Diagnostic Mode finishes, suggesting mistake codes are still kept. Mistake Codes must be cleared from the electronic control memory manually. To get rid of the non-flashing SOLUTION annunciator and the mistake codes, the issue needs to be fixed and also the device has to be ON, after that:.
Error Code Table
CODE | INDICATION |
05 | Refrig. cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
06 | Refrig. evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
07 | Freezer cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
08 | Freezer evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
20 | Defrost under-heat with no voltage feedback through Gray/White wire at defrost start |
21 | Defrost overheat |
22 | No voltage feedback through Gray/White wire at defrost start |
23 | Defrost overheat with no voltage feedback through Gray/White wire at defrost start |
24 | Defrost under-heat |
30 | N/A |
40 | Excessive Freezer Compressor Run |
50 | Excessive Refrigerator Compressor Run |
Error Code | CAUSE | SOLUTION |
Error Code 85 | The variable speed compressor is overheating | This may indicate low levels of refrigerant in the unit caused by a leak in the refrigerator’s sealed system. Another potential cause for this error is the refrigerator is drawing excessive electrical power causing the system to overheat. Both issues require the service of a qualified technician to resolve. |
Error Code 85
A. If “EE” for refrigerator compartment was shown as well as “SERVICE” flashing, inspect the following:.