MODELS:
DF30 – DF36 – DF48 – DF60 DF30-3 – DF36-3 – DF48-3 – DF60-3 DF30-4 – DF36-4 – DF48-4 – DF60-4
VERSION ATTRIBUTES:
DIAGNOSTIC MODE:
INITIATING DIAGNOSTIC MODE:
To initiate Diagnostic Mode, oven control knob bezel must be in the OFF position. Now, press and hold CLOCK key and TIMER key for 3 seconds. (See Figure 3-60)
The ambient cavity temperature will be displayed in the temperature readout knob. Now, turn the oven temperature readout knob to the right seven separate times, this will toggle from error code 1 thru 7. (See Figure 3-62)
To return to error code number one, turn oven temperature readout knob to the left seven separate times. (See Figure 3-63)
The software version will be displayed in the hours and minutes display of the clock. (See Figure 3-64)
NOTE:
MISTAKE INDICATORS:
Mistake codes can offer a visual and also distinct alarm. The aesthetic indicator will be “Err” presented in the Cook Time figures and also the number or letter of the mistake code will be displayed in the Stop Time digits of the Electronic Control Real Estate. The Oven Temperature level Readout Handle will certainly likewise show “Err” in the display home window. The last seven errors will certainly be kept in the EEPROM for recall when in analysis setting.
ERROR CODE | POSSIBLE CAUSE | TEST / ACTION |
7 | SPI Communication lost from ECH to the Control Board as reported by Control Board | Code reflects that the ECH cannot fine the Control Board. Replace cable first. Replace ECH if replacing cable does not correct problem. |