MODELS:
DF30 – DF36 – DF48 – DF60 DF30-3 – DF36-3 – DF48-3 – DF60-3 DF30-4 – DF36-4 – DF48-4 – DF60-4
MODEL ATTRIBUTES:
DIAGNOSTIC MODE:
Issues Related To the Surface Burners:
PROBLEM | POSSIBLE CAUSE | TEST / ACTION |
NO BROIL | Loose or defective wire connection | Repair or replace wire connections or wires |
Open element | Check for error codes in diagnostic mode. Perform element testing procedure. Replace if defective | |
Shorted element | Check for error codes in diagnostic mode. Perform element testing procedure. Replace if defective | |
Open or Shorted RTD | Initiate diagnostic mode, check for error codes | |
Thermo Limiter open or tripped | Ohm limit, replace if defective. Reset limit | |
Relay board failure | Perform relay board testing procedure. Replace if defective |